  • Ckj5-63a Ac Low Voltage Vacuum Contactor

    Ckj5-63a Ac past kuchlanishli vakuum kontaktori

    Asosiy texnik parametrlar Model Nominal kuchlanish (V) Nominal oqimning asosiy zanjiri (A) Asosiy aloqa parametrlari Quvvat chastotasining pasayish qarshiligi V (samarali qiymat) Asosiy zanjir Boshqarish davri Masofa (mm) Haddan tashqari harakatlanish (mm) Yakuniy bosim (N) Asosiy zanjir Yordamchi zanjirni boshqarish sxema CKJ5-63 1140 36,110,220,380 63 1,6 ± 0,2> 0,8 30 ± 5 4200 2500 2000 Model Ishlab chiqarish quvvati Buzilish quvvati Cheklangan tok (A) Elektrning ishlash muddati Mexanik ...
  • Ckg4-160,250,400,630/12-5 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-5 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar modeli CKG4-160-630 / 12-5 Asosiy zanjirning nominal kuchlanishi (KV) 12 12 12 12 Asosiy zanjirning nominal oqimi (A) 160 250 400 630 Asosiy elektronni ishlab chiqarish qobiliyati (A / 100 Ops.) 1600 2500 4000 6300 Asosiy elektron uzilish qobiliyati (A / 25 Ops.) 1280 2000 3200 5000 Maksimal uzilish qobiliyati (A / 3 Ops.) 3200 3200 4000 6300 Mexanik ishlash muddati (Ops.) 1000000 1000000 1000000 1000000 Asosiy zanjir uchun quvvat chastotasi qarshilik kuchlanishi ( kV) 42 42 ...
  • Jcz5-7.2d(J)/160,250,400,630 Ac High Voltage Vacuum Contactor

    Jcz5-7.2d (J) / 160,250,400,630 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar Model Nominal kuchlanish (V) Nominal oqimning asosiy zanjiri (A) Asosiy aloqa parametrlari Quvvat chastotasining pasayish qarshiligi V (samarali qiymat) Asosiy zanjir Boshqarish davri Masofa (mm) Haddan tashqari harakatlanish (mm) Yakuniy bosim (N) Asosiy zanjir Yordamchi zanjirni boshqarish elektron JCZ5-7.2D (J) / 160 7200 100.22 160 4.5 ± 0.5 1.5 ± 0.5> 85N 32000 2500 2000 JCZ5-7.2D (J) / 250 7200 100.22 250 4.5 ± 0.5 1.5 ± 0.5> 85N 32000 2500 2000 JCZ5-7.2 D (J) / 400 7200 100,22 400 4,5 ± 0,5 1,5 ± 0 ...
  • Jcz5-12d(J)/160,250,400,630 Ac High Voltage Vacuum Contactor

    Jcz5-12d (J) / 160,250,400,630 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar Model Nominal kuchlanish (V) Nominal oqimning asosiy zanjiri (A) Asosiy aloqa parametrlari Quvvat chastotasining pasayish qarshiligi V (samarali qiymat) Asosiy zanjir Boshqarish davri Masofa (mm) Haddan tashqari harakatlanish (mm) Yakuniy bosim (N) Asosiy zanjir Yordamchi zanjirni boshqarish elektron JCZ5-12D (J) / 160 12000 100.22 160 5 ± 0.5 1.5 ± 0.5> 85N 42000 2500 2000 JCZ5-12D (J) / 250 12000 100.22 250 5 ± 0.5 1.5 ± 0.5> 85N 42000 2500 2000 JCZ5-12D (J ) / 400 12000 100.22 400 5 ± 0.5 1.5 ± 0.5> 85 ...
  • Ckg4-160,250,400,630/12-4 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-4 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar modeli CKG4-160-630 / 12-4 Asosiy zanjirning nominal kuchlanishi (KV) 12 12 12 12 Asosiy zanjirning nominal oqimi (A) 160 250 400 630 Asosiy zanjirni ishlab chiqarish qobiliyati (A / 100 Ops.) 1600 2500 4000 6300 Asosiy elektron uzilish qobiliyati (A / 25 Ops.) 1280 2000 3200 5000 Maksimal uzilish qobiliyati (A / 3 Ops.) 3200 3200 4000 6300 Mexanik ishlash muddati (Ops.) 1000000 1000000 1000000 1000000 Asosiy zanjir uchun quvvat chastotasi qarshilik kuchlanishi ( kV) 42 ...
  • Ckg4-160,250,400,630/12-2 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-2 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar modeli CKG4-160-630 / 12-2 Asosiy zanjirning nominal kuchlanishi (KV) 12 12 12 12 Asosiy zanjirning nominal oqimi (A) 160 250 400 630 Asosiy zanjirni ishlab chiqarish qobiliyati (A / 100 Ops.) 1600 2500 4000 6300 Asosiy elektron uzilish qobiliyati (A / 25 Ops.) 1280 2000 3200 5000 Maksimal uzilish qobiliyati (A / 3 Ops.) 3200 3200 4000 6300 Mexanik ishlash muddati (Ops.) 1000000 1000000 1000000 1000000 Asosiy zanjir uchun quvvat chastotasi qarshilik kuchlanishi ( kV) 42 42 ...
  • Ckg4-160,250,400,630/12-1 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-1 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar modeli CKG4-160-630 / 12-1 Asosiy zanjirning nominal kuchlanishi (KV) 12 12 12 12 Asosiy zanjirning nominal oqimi (A) 160 250 400 630 Asosiy zanjirni ishlab chiqarish qobiliyati (A / 100 Ops.) 1600 2500 4000 6300 Asosiy o'chirish qobiliyati (A / 25 Ops.) 1280 2000 3200 5000 Maksimal uzilish qobiliyati (A / 3 Ops.) 3200 3200 4000 6300 Mexanik ishlash muddati (Ops.) 1000000 1000000 1000000 1000000 Asosiy zanjir uchun quvvat chastotasi qarshilik kuchlanishi ( kV) 42 42 ...
  • Ckg4-12/160,250,400,630 Ac High Voltage Vacuum Contactor

    Ckg4-12 / 160,250,400,630 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar Model Nominal kuchlanish (V) Nominal oqimning asosiy zanjiri (A) Asosiy aloqa parametrlari Quvvat chastotasining pasayish qarshiligi V (qarshilik qiymati) Asosiy zanjir Boshqarish davri Masofa (mm) Haddan tashqari harakatlanish (mm) Yakuniy bosim (N) Asosiy zanjir Yordamchi zanjirni boshqarish elektron CKG4-12 / 160 12000 100.220,380 160 5 ± 0,5 5 ± 0.2> 85N 42000 2500 2000 CKG4-12 / 250 12000 100.220,380 250 5 ± 0.5 5 ± 0.2> 85N 42000 2500 2000 CKG4-12 / 400 12000 100 ...
  • Ckg3-7.2/160,250,400,630-5 Ac High Voltage Vacuum Contactor

    Ckg3-7.2 / 160,250,400,630-5 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar modeli CKG3-7.2 / 160-630-5 Asosiy zanjirning nominal kuchlanishi (KV) 7.2 7.2 7.2 7.2 Asosiy zanjirning nominal oqimi (A) 160 250 400 630 Asosiy elektronni ishlab chiqarish qobiliyati (A / 100 Ops.) 1600 2500 4000 6300 Asosiy elektron uzilish qobiliyati (A / 25 Ops.) 1280 2000 3200 5000 Maksimal uzilish qobiliyati (A / 3 Ops.) 3200 3200 4000 6300 Mexanik ishlash muddati (Ops.) 1000000 1000000 1000000 1000000 Asosiy zanjir uchun quvvat chastotasi qarshilik kuchlanishi ( kV) ...
  • Ckg3-7.2/160,250,400,630 Ac High Voltage Vacuum Contactor

    Ckg3-7.2 / 160,250,400,630 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar modeli CKG3-7.2 / 160-630 Asosiy zanjirning nominal kuchlanishi (KV) 7.2 7.2 7.2 7.2 Asosiy zanjirning nominal oqimi (A) 160 250 400 630 Asosiy zanjirni ishlab chiqarish qobiliyati (A / 10 Ops.) 1600 2500 4000 6300 uzilish qobiliyati (A / 10 Ops.) 1280 2000 3200 5000 Maksimal uzilish qobiliyati (A / 3 Ops.) 3200 3200 4000 6300 Mexanik ishlash muddati (Ops.) 1000000 1000000 1000000 1000000 Muhandislik qulflash muddati (Ops.) 100000 100000 100000 100000 ...
  • Ckg3-7.2/160,250,400,630-4 Ac High Voltage Vacuum Contactor

    Ckg3-7.2 / 160,250,400,630-4 Ac yuqori voltli vakuum kontaktori

    Asosiy texnik parametrlar modeli CKG3-7.2 / 160-630-4 Asosiy zanjirning nominal kuchlanishi (KV) 7.2 7.2 7.2 7.2 Asosiy zanjirning nominal oqimi (A) 160 250 400 630 Asosiy elektronni ishlab chiqarish qobiliyati (A / 100 Ops.) 1600 2500 4000 6300 Asosiy elektron uzilish qobiliyati (A / 25 Ops.) 1280 2000 3200 5000 Maksimal uzilish qobiliyati (A / 3 Ops.) 3200 3200 4000 6300 Mexanik ishlash muddati (Ops.) 1000000 1000000 1000000 1000000 Asosiy zanjir uchun quvvat chastotasi qarshilik kuchlanishi ( kV) ...
  • Ckj20-630,800/2000a Ac Vacuum Contactor

    Ckj20-630,800 / 2000a Ac vakuum kontaktori

    Asosiy texnik parametrlar modeli CKJ20-630 / 1140 CKJ20-800 / 1140 Asosiy zanjirning nominal kuchlanishi (V) 1140 1140 Asosiy zanjirning nominal oqimi (A) 630 800 Asosiy zanjirni ishlab chiqarish qobiliyati (A / 10 Ops.) 6000 8000 qobiliyat (A / 10 Ops.) 4800 6400 Maksimal uzilish qobiliyati (A / 3 Ops.) 6000 7500 Elektr quvvati AC3 (Million marta) 90 Elektr quvvati AC4 (Million marta) 6 Mexanik ishlash muddati (Million marta) 300 Nominal ish chastotasi AC3 ( Ops. / H) 600 R ...