ZN12-12 / 40,5 yopiq HV vakuumli o'chirgich - bu 3 fazali AC 50Hz 12kV / 40,5KV yopiq o'chirish moslamasi.
♦ O'rnatish usuli: olinadigan turdagi, sobit turdagi;
♦ Operatsion mexanizmi: bahor ope reyting mexanizmi;
♦ Ilova: kommutator GBC-35, JYN1-35.
Atrof-muhit sharoitlari
♦ Atrof-muhit harorati: -25 ° C ~ + 40 ° C;
♦ Balandligi:
♦ Nisbiy namlik: kunlik o'rtacha ;
♦ Zilzila intensivligi:
♦ Yong'in, portlash xavfi, jiddiy iflos, kimyoviy korroziya, shuningdek kuchli tebranish bo'lmagan joylar.
Asosiy texnik parametrlar
ZN12-12
Yo'q | Element | Birlik | Qiymat | ||||
1 | Nominal kuchlanish | kV | |||||
2 | Nominal oqim | A | 630, 1250, 1600 | 1250, 1600,2000, 2500,3150 | 2000, 2500, 3150,4000 | ||
3 | Nominal qisqa tutashuvni uzish oqimi | kA | 20 | 25 | 31.5 | 40 | 50 |
4 | Dinamik barqarorlik oqimi (pik) | kA | 50 | 63 | 80 | 100 | 125 |
5 | 4s termal barqarorlik oqimi | kA | 20 | 25 | 31.5 | 40/3s | 50/3s |
6 | Nominal qisqa tutashuv oqimi | kA | 50 | 63 | 80 | 100 | 125 |
7 | Qisqa tutashuv oqimining uzilish raqami | marta | 30 | 12 | |||
8 | Nominal ishlash ketma-ketligi | CO-0,3S-CO-180S-CO | O-180S-CO-180S-CO | ||||
9 | Mexanik hayot | marta | 10000 | 6000 | |||
10 | Nominal oqimning uzilish raqami | marta | 10000 | 6000 | |||
11 | Nominal chaqmoq impulsiga chidamli kuchlanish (to'liq to'lqin) | kV | 75 | ||||
12 | Nominal qisqa muddatli quvvat chastotasi tokiga chidamli (1 min) | kV | 42 | ||||
13 | Yopilish vaqti | Xonim | ≤75 | ||||
14 | Ochilish vaqti | Xonim | ≤65 | ||||
15 | Energiyani saqlash dvigatelining quvvati va nominal kuchlanishi | W/V | 275 Vt/ 110 V, 220 V | ||||
16 | Energiyani saqlash vaqti | s |
|
Yo'q | Element | Birlik | Qiymat |
17 | Yopish bobinining nominal kuchlanishi | IN | 110V, 220V |
18 | Ochilish lasanining nominal kuchlanishi | IN | |
19 | Qulflash lasanining nominal kuchlanishi | IN | |
20 | Chiqarishning nominal oqimi | A | 5 |
yigirma bir | Yordamchi kalitning nominal oqimi | A | AC10A, DC5A |
ZN12-40,5
Yo'q | Element | Birlik | Qiymat | |
1 | Nominal kuchlanish | kV | 40.5 | |
2 | Nominal oqim | A | 1250, 1600, 2000 | 1250, 1600,2000,2500 |
3 | Nominal qisqa tutashuvni uzish oqimi | kA | 20, 25 | 31.5 |
4 | Dinamik barqarorlik oqimi (pik) | kA | 50, 63 | 80 |
5 | 4s termal barqarorlik oqimi | kA | 20, 25 | 31.5 |
6 | Nominal qisqa tutashuv oqimi (tepalik) | kA | 50, 63 | 80 |
7 | Qisqa tutashuv oqimining uzilish raqami | marta | 30 | 20 |
8 | Nominal ishlash ketma-ketligi | CO-0,3S-CO-180S-CO | ||
9 | Nominal chaqmoq impulsiga chidamli kuchlanish (to'liq to'lqin) | kV | 180 | |
10 | Nominal qisqa muddatli quvvat chastotasi tokiga chidamli (1 min) | kV | 95 | |
11 | Yopilish vaqti | Xonim | ≤90 | |
12 | Ochilish vaqti | Xonim | ≤75 | |
13 | Mexanika! hayot | marta | 10000 | 60 000 |
14 | Nominal oqimning uzilish raqami | marta | 10000 | 60 000 |
15 | Nominal kondansatör bankining uzilish oqimi | A | 630 | |
Energiyani saqlash dvigatelining kuchi | IN | 275 | ||
17 | Energiyani saqlash dvigatelining nominal kuchlanishi | IN | ≃110V, 220V | |
18 | Energiyani saqlash vaqti | s | ≤15 | |
19 | Yopish va ochish lasanining nominal kuchlanishi | IN | ≃110V, 220V | |
20 | Haddan tashqari oqim chiqarishning nominal oqimi | A | 5 | |
yigirma bir | Yordamchi kalitning nominal oqimi | A | AC10A, DC5A |
Umumiy tuzilish chizmasi va o'rnatish hajmi (birlik: mm)
♦ZN12-12 (eğimli o'rnatilgan)
Eslatma: 360 mm o'lcham 2000 A dan yuqori oqim uchun, 2000 A ostida, o'lchami 350 mm.
E'tibor bering, rasmda (215) L3 = 516 mm bo'lganda, o'lcham 215 mm ni bildiradi.
1600A ostida: yuqori va pastki chiqish terminali teshigi 2-M12
2000A dan yuqori: yuqori va pastki chiqish terminali teshigi 4-M12
Turi | L | L1 | L2 | L3 | Izohlar |
ZN12-12 | 210 | 586 | 610 | 516 | Fazalararo bo'linish bilan |
230 | 620 | 650 | 565 | ||
250 | 700 | 740 | 565 | ||
275 | 696 | 720 | 516 |
♦ZN12-12B (tepa o'rnatilgan)(569575)
Eslatma: (575) va (364) qisqa tutashuvni uzish oqimi 40kA yoki undan yuqori bo'lsa, o'lchamlar 575 mm, 364 mm ni bildiradi.
Yuqori va pastki chiqish terminali teshigi 4-M12
Izoh: (215) L3=516mm bo'lganda anglatadi;o'lchami 215 mm.
Turi | L | L1 | L2 | L3 |
ZN12-12B | 210 | 586 | 610 | 516 |
230 | 620 | 650 | 565 | |
250 | 700 | 740 | 565 | |
275 | 696 | 720 | 516 |
Izohlar Fazalararo bo'linish bilan